XK-W2001 Digital Temperature Humidity Controller Socket AC 110-220V Thermostat Regulator Socket Outlet EU plug With NTC Sensor

₺949,00
+ ₺365,99 Kargo

XK-W2001 Digital Temperature Humidity Controller Socket AC 110-220V Thermostat Regulator Socket Outlet EU plug With NTC Sensor

  • Marka: Unbranded

XK-W2001 Digital Temperature Humidity Controller Socket AC 110-220V Thermostat Regulator Socket Outlet EU plug With NTC Sensor

  • Marka: Unbranded
Önerilen Perakende Fiyatı: ₺7.190,00
Fiyat: ₺949,00
Kazancınız: ₺6.241,00 (86%)
Satıcı:
₺949,00
+ ₺365,99 Kargo

Stokta var

14 Günlük İade Politikası

Ödeme yöntemleri:

Tanım

XK-W2001 Digital Temperature Humidity Controller Socket AC 110-220V Thermostat Regulator Socket Outlet EU plug With NTC Sensor

XK-W2001 Digital Temperature Humidity Controller Socket AC 110-220V Thermostat Regulator Socket Outlet EU plug With NTC Sensor Product Selling Points 1Widely used 2: Beautiful appearance 3Convenient and simple 4: 1M waterproof wire probe 5:Easy to set up and understand Product name:Microcomputer temperature controller Temperature measurement range:-50~110~c Temperature control range:-50~110~c Temperature measurement precision:0.2 Temperature control accuracy: 0.1 C Measurement input: NTC10K L=1 meter waterproof probe Input power:110V-220V Output power: 1500W Output type: direct output Output Capacity:Maximum 10A Dimension:120*59*30mm Code and Function Introduction PO setup startup temperature Press the setup button to enter the internal menu, the default display is P0, press the setup button again to set the desired start temperature by pressing the up and down buttons. P1 set stop temperature Press the setup button to enter the internal menu, the digital display is P0, switch to P1 by pressing the up and down buttons, press the setup button again and set the desired stop temperature by pressing the up and down buttons. P2 Setting Temperature Correction The same way to enter the internal menu, switch to P2 by up and down buttons, press the setup key again, set the desired calibration temperature by up and down buttons. In the setting, if the detected temperature value is 0.5 larger than the actual temperature value, then the calibration temperature to be set is -0.5. If the detected temperature value is 1 smaller than the actual temperature value, the calibration temperature to be set is 1. Detected temperature calibration temperature = actual temperature. P3 Setting delayed start The same way into the internal menu, through the up and down keys to switch to P3, once again press the setup key, through the up and down keys to set the desired delay time (in minutes). Delay start is generally used for compressor refrigeration, if used in refrigerators and freezers, this value needs to be set, according to the size of the compressor back to the general set value of 3-6 minutes, if you are not used to control the compressor or do not need to delay the function, directly skip this item! Heating mode setting mode Setting: start temperature < stop temperature (the program automatically determines the working mode as heating mode) Setting method. Press the setup button to enter the internal menu, set the start temperature by setting the P0 value, set the stop temperature by setting the P1 value. Use Case: Control water heater, heating up to 50, stop temperature by setting P1 value. Control the water heater, heating to 50 to stop, the temperature falls back to 40 to start heating again, how to set? Step 1: Make sure the working mode is heating mode, start temperature < stop temperature. Step 2: Press setup button to enter internal menu, select P0 and press setup button, set P0 value to 40. Step 3:Press setup key to enter internal menu,select P1 and press setup key,set P1 value to 50. Cooling mode setting method Setting key: Start temperature > Stop temperature (the program automatically determines the working mode as cooling mode) Setting method. Press setup key to enter internal menu, set start temperature by setting P0 value, set stop temperature by setting P1 value. Use Case: Control the cabinet radiator to dissipate the heat. Control cabinet radiator, heat dissipation to 26 to stop, the temperature rises to 30 to start the radiator again, how to set? Step 1: Make sure the working mode is cooling mode, start temperature > stop temperature. Step 2:Press Setup to enter the internal menu, select P0 and press Setup to set the P0 value to 30. Step 3:Press setup key to enter internal menu, select P1 and press setup key, set P1 value to 26. Tips. When setting the heating mode, if the set temperature value is inverted accidentally, the output indicator will not light up and the load will not work, if the above situation occurs after the setting is completed, you can check whether the set temperature value is inverted or not. List 1*Temperature controller _x000D_
  • Fruugo Kimliği: 405837021-860559656
  • EAN: 7709461275486

Ürün Güvenlik Bilgileri

Lütfen aşağıda özetlenen bu ürüne özel ürün güvenlik bilgilerine bakın.

Aşağıdaki bilgiler bu ürünü satan bağımsız üçüncü taraf perakendeci tarafından sağlanmaktadır.

Ürün Güvenlik Etiketleri

CE Mark
Güvenlik Uyarıları: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
İçindekiler: Octinoxate 6.2864%
Üretici Parça Numarası: EW301152
Model Numarası: EW858396
Seri numarası: EW003632
Parti Numarası: EW001718

Teslimat ve İade

3 gün içinde kargoya verilir

  • STANDARD: ₺365,99 - Arasında teslimat Cum 09 Ocak 2026–Per 15 Ocak 2026

Kargo çıkış noktası Çin.

Sipariş ettiğiniz ürünlerin size bütün ve belirttiğiniz özelliklere göre teslim edilmesi için elimizden gelenin en iyisini yapıyoruz. Fakat, bütün gelmeyen veya siparişiniz ettiğinizden farklı çıkan bir ürünün elinize ulaşması ya da siparişinizden başka bir sebepten ötürü memnun kalmamanız durumunda, siparişi veya siparişe dahil ürünlerden herhangi birini iade edebilir ve ürünler için tam para iadesi alabilirsiniz. Tam iade politikasını görüntüle