Tanım
Feature:1. [High Accuracy] The gloss meter can measure in real time, no key operation is required, and the measurement is fast and accurate, so you can use it with confidence.2. [Ambient Temperature Compensation] Glossmeter has the function of ambient temperature compensation, the value is stable, and long period calibration is allowed.3. [USB Transmission] Supports USB transmission, dedicated operating software, and can be operated online with a computer and complete the test report.4. [QC Judgment Function] Goss meter adopts ergonomic design, beautiful appearance, comfortable grip, and QC judgment function, which can realize rapid detection of incoming materials.5. [Low Power Consumption] Built in rechargeable lithium battery, has ultra low power consumption, and it can be used continuously for more than 32 hours on a single charge.Specification:Item Type: Gloss MeterModel: LS195Material: ABSBattery: 1 x Rechargeable lithium battery 3.7V 650mAh (Battery Included)Purpose: Sampling and comparison of gloss measurementApplication: Paint, coating, ink, plastic, paper, ceramic tile, ceramic, stone, metal, electroplating layerMeasuring Angle: 60Measuring Spot: Approx. 9 x 15 mm / 0.4 x 0.6 inMinimum Size of Test Object: Approx. 20 x 10 mm / 0.8 x 0.4 inMeasuring Range: 0-200GUResolution: 0.1GURepeatability:0-100GU: 0.2GU100-200GU: 0.2% of readingReproducibility:0-100GU: 0.5GU100-200GU: 0.5% of readingZero Error: 0.1GUIndication Error:0-100GU: 1.5GU100-200GU: 1.5% of readingSystem Language: Chinese, EnglishDisplay: 240 x 128 dot matrix LCDCharging Interface: USB (Type C)Data Interface: USBOperating Temperature Range: 10-45 , 0-85%RH (non condensing)Storage Temperature Range: -10-60, 0-85%RH (no condensation)QC Judgment: Ambient Temperature Compensation: How To Use:1. Power on/offPower on: In the off state, short press the instrument button to power on.Shut down: Long press the instrument button to shut down; the instrument will automatically shut down when there is no operation for more than 3 minutesmachine.2. Parameter settingIn the shutdown state, long press the instrument button for 3S to enter the parameter setting mode:A. Language (Language)Short press the button to select Chinese or English, long press the button for 3S to complete the setting, and enter the following setting item.B. Mode selectionShort press the button to select normal mode or QC mode, long press the button for 3S to complete the setting, exit the setting and enter the calibration interface.3. Equipment calibrationPut the instrument on the standard board and turn on the opportunity to enter the calibration interface. The user can perform the calibration operation according to the calibration prompt, and the measurement interface will be entered after the calibration is passed. If the instrument is turned on without putting it on the standard board, it will skip the calibration and enter the measurement interface directly. If it prompts that the calibration failed, the possible reasons are as follows:The standard board is dirty, please wipe the standard board clean with a special lens cloth, and then buckle the host into the base.The host is not close to the standard board, please buckle it into the base again.When the ambient temperature changes significantly, the instrument temperature and the ambient temperature should be close to each other, and after confirming that the lens in the test port of the instrument and the standard plate of the base are not dew, restart the measurement.The attenuation of the light source can not be used normally, and it needs to be returned to the factory for inspection and repair.When the instrument prompts "Calibration failed", you can long press the button to skip the calibration.4. Measure(1) Normal modeIf the instrument is set to normal mode, after the calibration of the instrument is completed, remove the base and place the measuring port of the instrument on the surfaces of the object to be measured, and the instrument will display the measured value at that place in real time. Short press the button, the lower left corner of the interface displays the "HOLD" sign, and the measurement data is held on the LCD. If you need to measure again, press the button to cancel the "HOLD" state and return to the "Measuring" state.(2) QC modeIf the instrument is set to QC mode, after the instrument is calibrated, remove the base, place the measuring port of the instrument on the surfaces of the object to be measured, and short-press the button to perform the measurement. After the measurement, the measured value will be judged whether it is qualified. The range of the upper and lower limits must be set by PC software. For specific operations, please refer to the "Gloss Meter Software Operation Manual"..Package List:1 x Glossmeter (Battery Included)1 x Data Line1 x Cleaning Cloth1 x Calibration Report1 x ManualNote:1. The instrument has temperature compensation and allows longterm calibration. It is recommended to
-
Fruugo Kimliği:
387488674-831844514
-
EAN:
6950044985181
Ürün Güvenlik Bilgileri
Lütfen aşağıda özetlenen bu ürüne özel ürün güvenlik bilgilerine bakın.
Aşağıdaki bilgiler bu ürünü satan bağımsız üçüncü taraf perakendeci tarafından sağlanmaktadır.
Ürün Güvenlik Etiketleri
Güvenlik Uyarıları:
Replacement must be performed with the assistance of a professional
İçindekiler:
75% plastic and 25% metal