Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

₺1.199,00
+ ₺758,99 Kargo

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

  • Marka: Unbranded

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

  • Marka: Unbranded
Önerilen Perakende Fiyatı: ₺1.849,00
Fiyat: ₺1.199,00
Kazancınız: ₺650,00 (35%)
Satıcı:
₺1.199,00
+ ₺758,99 Kargo

Stokta var

14 Günlük İade Politikası

Ödeme yöntemleri:

Tanım

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

DC 12V DDC-431 Timer Delay Relay Switch Digital Data Save Delay Controller DC 6V-30V - Powerful function with one-button emergency stop (STOP button), reverse connection protection, no damage during reverse polarity, power-off memory - Features sleep mode: after 5 minutes of inactivity, display automatically turns off; wake by pressing any button - Supports independent settings for OP, CL, and LOP parameters; settings are saved automatically upon power down, meeting a wide range of application needs Product Manual: Working voltage: DC 6V–DC 30V (wide voltage with reverse polarity protection) Trigger signal source: High-level trigger DC 3.0V–24V; signal ground connected to system ground for improved anti-interference performance; can be shorted to ground Output capacity: DC 30V/10A or AC 250V/10A Product size: 64mm x 35mm x 19.3mm Mounting hole diameter: 3mm Operating temperature: -40°C to 85°C Operating Modes: P1 Mode: After signal trigger, relay turns on for OP time, then turns off. During OP time: P1.1: Signal triggered again P1.2: Signal re-triggers timing P1.3: Signal resets, relay disconnects, timing stops P2 Mode: Upon trigger signal, relay turns off for CL time, then turns on for OP time. After timing completes, relay turns off. P3.1: Trigger signal initiates relay on for OP time, off for CL time, then repeats cycle. Number of cycles (LOP) can be set. If signal is given again during cycle, relay disconnects and timing stops. P3.2: No trigger required after power-on. Relay turns on for OP time, off for CL time, and repeats cycle. Number of cycles (LOP) can be set. P4 Mode: Signal hold function. When trigger signal is present, timing resets and relay remains on. When signal is removed, relay turns off after OP timing. If signal reappears during timing, timing resets. Relay Enable Mode: ON: Relay can conduct during OP time OFF: Relay is disabled and remains off Short press STOP button on main interface to switch between ON and OFF. Current state flashes briefly before returning to main interface. This provides emergency stop functionality. Sleep Mode (long press STOP to view current mode): C-P Sleep Mode: Display turns off automatically after 5 minutes of inactivity; program continues running O-d Normal Mode: Display remains on continuously Press and hold STOP button for 2 seconds to toggle between C-P and O-d modes. Current mode flashes briefly before returning to main interface. Timing Range Selection: After setting parameter in mode selection interface, press STOP button to select timing range: XXX. Decimal point at units place: 1 second to 999 seconds XX.X Decimal point at tenths place: 0.1 seconds to 99.9 seconds X.X.X All decimal points illuminated: 1 minute to 999 minutes Example: To set OP to 3.2 seconds, set decimal point to tenths place; display shows 03.2 Parameters: OP – On time CL – Off time LOP – Cycle count (1–999); 0 indicates infinite loop Parameters are independent and shared across modes. For example, if OP is set to 5 seconds in P1.1, switching to P1.2 will retain OP = 5 seconds unless changed. Display 000 on main interface and press SET button to view OPL, LOP, and corresponding values In modes with only OP (e.g., P1.1, P1.2, P1.3), short press SET to display OP and time In modes with OP, CL, LOP (e.g., P3.1, P3.2), short press SET to display OP, CL, and LOP with respective values After mode setup, press SET on main interface to easily review current mode parameters Parameter Setting Procedure: 1) Determine desired relay operating mode 2) From main interface (module displays current mode on power-up, default P1.1), press and hold SET button for 2 seconds, then release to enter mode selection interface 3) Select desired mode for configuration
  • Fruugo Kimliği: 405214894-859612189
  • EAN: 8324364702694

Teslimat ve İade

3 gün içinde kargoya verilir

  • STANDARD: ₺758,99 - Arasında teslimat Per 15 Ocak 2026–Sal 27 Ocak 2026

Kargo çıkış noktası Çin.

Sipariş ettiğiniz ürünlerin size bütün ve belirttiğiniz özelliklere göre teslim edilmesi için elimizden gelenin en iyisini yapıyoruz. Fakat, bütün gelmeyen veya siparişiniz ettiğinizden farklı çıkan bir ürünün elinize ulaşması ya da siparişinizden başka bir sebepten ötürü memnun kalmamanız durumunda, siparişi veya siparişe dahil ürünlerden herhangi birini iade edebilir ve ürünler için tam para iadesi alabilirsiniz. Tam iade politikasını görüntüle

Ürün Uyumluluk Ayrıntıları

Lütfen aşağıda özetlenen bu ürüne özel uyumluluk bilgilerine bakın.

Aşağıdaki bilgiler bu ürünü satan bağımsız üçüncü taraf perakendeci tarafından sağlanmaktadır.

Üretici:
Aşağıdaki bilgiler, Fruugo tarafında satılan bahsi geçen ürünün üreticisinin irtibat bilgilerini ortaya koymaktadır.

  • Jiang Yan
  • Guangzhou Ruicai E-commerce Co., Ltd.
  • Room D2709, 203, 2nd Floor, No. 4, Yuejia 2nd Street,Shimen Street, Baiyun District,Guangzhou City,Guangdong Province
  • Guangzhou
  • CN
  • 510420
  • lu61027yeyamei632@163.com
  • 13192975727

AB sınırları içerisindeki Sorumlu Kişi:
Aşağıdaki bilgiler AB sınırları içerisindeki Sorumlu Kişi’nin irtibat bilgilerini ortaya koymaktadır. Sorumlu kişi AB içerisinde konumlu olan atanmış iktisadi işlemcidir, Avrupa Birliği içerisinde satılan bahsi geçen ürün ile ilgili uygunluk yükümlülüklerinden sorumludur.

  • Van Lavazza
  • Y & H S.R.L.
  • Via Gravina 21 MT matera,Trani,Puglia
  • Trani
  • Italy
  • 75100
  • itlyhsrl@gmail.com
  • 0039 3917722149