Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

₺22.690,00
ÜCRETSİZ Kargo

Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

Digital Manifold Meter For Air Conditioner Refrigerant Leak, Fault Check, Vacuum, And Temperature Testing

Önerilen Perakende Fiyatı: ₺45.390,00
Fiyat: ₺22.690,00
Kazancınız: ₺22.700,00 (50%)
Satıcı:
₺22.690,00
ÜCRETSİZ Kargo

Stokta var

Biz aşağıdaki ödeme yöntemlerini kabul ediyoruz

Tanım

AC3000 digital manifold is a professional  instrument for installation, testing and maintenance of refrigeration equipment such as air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements ( with optional dual temperature probes ), a 32-bit digital processor and a large LCD in one easy-to-use instrument with the following main functions. 1.Pressure and Saturation Temperature. 2.Vacuum Operation. 3.Pressure Leak Test with recording. 4.Direct T1 T2 Temperature, Real-time Super heat and Sub cooling Simultaneously Display with Optional Two Clamp-on Temperature Probes. 5.89 Refrigerant Profiles Stored in The Instrument. 6.Automatic Multi-unit Pressure Conversion. 7.Automatic Temperature ℃/℉ Conversion. It is the right one you have to do the job right. Pressure Measuring: 1. Turn off the blue valve and red valve. 2. Turn on the instrument. Then verify that LCD displays the status of the pressure test.If not,press the function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero. 4. Press R+/ R- buttons , Unit button and ℃/℉ button to select tested refrigerant and reading display respectively. 5. If the clamp-on temperature probes have been connected to the instrument, the real-time temperature will be displayed.If not, no display of it. 6. Connect the instrument to the refrigeration system according to the chart below. 7. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. 8. When the refrigeration system stops, turn on the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. 9. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. 10. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. 11. Shut down the refrigeration system,make sure all valves are turned off , then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. Vacuum Operation: 1. Turn off the blue valve and red valve. 2. Power on the instrument. Then make sure the LCD displays vacuum test status.If not, press the Function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero 4. Press the unit button to adjust the reading unit. 5. Connect the instrument to the refrigeration system.(Connected clamp-on temperature probes will not affect the operation.) 6. Turn on the blue valve and red valve, and start the vacuum pump. 7. After the vacuum operation is completed,turn off the blue valve and red valve, then shut the vacuum pump. At this time,pressure leak test mode can be used to check leakage in the system ( Please refer to Pressure Leak Test). Pressure Leak Test: 1. The instrument is powered on with the blue and red valves turned off. 2. Press the Function button to pressure leak test mode.
  • Fruugo Kimliği: 184331743-393621310
  • EAN: 6264607529348

Ürün Güvenlik Bilgileri

Lütfen aşağıda özetlenen bu ürüne özel ürün güvenlik bilgilerine bakın.

Aşağıdaki bilgiler bu ürünü satan bağımsız üçüncü taraf perakendeci tarafından sağlanmaktadır.

Güvenlik Uyarıları: Keep out of reach of children under 36 months. Contains small parts that may present a choking hazard. Adult supervision required Please read and retain these instructions for future reference Remove all packaging before giving to children Keep away from fire and direct heat sources

Teslimat ve İade

2 gün içinde kargoya verilir

  • STANDARD: ÜCRETSİZ - Arasında teslimat Cum 10 Ekim 2025–Cum 31 Ekim 2025 - ÜCRETSİZ

Kargo çıkış noktası Amerika Birleşik Devletleri.

Sipariş ettiğiniz ürünlerin size bütün ve belirttiğiniz özelliklere göre teslim edilmesi için elimizden gelenin en iyisini yapıyoruz. Fakat, bütün gelmeyen veya siparişiniz ettiğinizden farklı çıkan bir ürünün elinize ulaşması ya da siparişinizden başka bir sebepten ötürü memnun kalmamanız durumunda, siparişi veya siparişe dahil ürünlerden herhangi birini iade edebilir ve ürünler için tam para iadesi alabilirsiniz. Tam iade politikasını görüntüle

Ürün Uyumluluk Ayrıntıları

Lütfen aşağıda özetlenen bu ürüne özel uyumluluk bilgilerine bakın.

Aşağıdaki bilgiler bu ürünü satan bağımsız üçüncü taraf perakendeci tarafından sağlanmaktadır.

Üretici:
Aşağıdaki bilgiler, Fruugo tarafında satılan bahsi geçen ürünün üreticisinin irtibat bilgilerini ortaya koymaktadır.

  • Ebox
  • Ebox Inc
  • Central Ave, Chino,CA,USA
  • Chino
  • US
  • 91710
  • f.help@ebox-inc.com
  • 805 539 4494
  • https://www.ebox-inc.com

AB sınırları içerisindeki Sorumlu Kişi:
Aşağıdaki bilgiler AB sınırları içerisindeki Sorumlu Kişi’nin irtibat bilgilerini ortaya koymaktadır. Sorumlu kişi AB içerisinde konumlu olan atanmış iktisadi işlemcidir, Avrupa Birliği içerisinde satılan bahsi geçen ürün ile ilgili uygunluk yükümlülüklerinden sorumludur.

  • Axitera GmbH
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt a. Main,
  • Hessen, Germany
  • Frankfurt am Main
  • DE
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848