DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

₺799,00
ÜCRETSİZ Kargo

DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

  • Marka: Unbranded

DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

  • Marka: Unbranded
Önerilen Perakende Fiyatı: ₺1.199,00
Fiyat: ₺799,00
Kazancınız: ₺400,00 (33%)
Satıcı:
₺799,00
ÜCRETSİZ Kargo

Stokta var

Biz aşağıdaki ödeme yöntemlerini kabul ediyoruz

Tanım

PO version (Self-locking) — Product Description and Key Details Key benefits - Provides reliable self-locking control for motor direction to prevent unintended reversals or stalls. - Simplifies external control: a momentary external forward or reverse command maintains motor motion after the switch is released, reducing operator effort. - Clear, safety-oriented limit behavior: short or transient limit signals reliably stop motion and require intentional restart, avoiding accidental restarts. How it works (functional summary) - PO versions are self-locking: when an external forward switch (K1) is pressed, the motor begins a forward rotation and remains rotating after the switch is released. The motor stops only when a reverse-turn signal (K2) or the forward-turn stop signal (SW1) is received. - Limit (stop) signals are trigger-type, level-activated inputs. If a forward rotation encounters a limit signal, motion is stopped immediately; the motor remains stopped even if the limit signal is removed. To resume forward movement, the forward rotation signal must be issued again. - Signal logic: inputs are active low. The product accepts standard three-wire NPN normally-open (NPN-NO) sensors. Inputs K1, K2, SW1, and SW2 conform to the same active-low specification. Features and attributes - Function: Self-locking directional control with defined limit/stop behavior for safe and predictable motor operation. - Compatibility: Accepts active-low control signals and three-wire NPN-NO sensors; K1, K2, SW1, SW2 are compatible with this signaling convention. - Performance behavior: Latching forward/reverse commands until a definitive stop or opposite command is received; limit inputs act as level-activated stops that persist until a restart command. - Size/material: Refer to the product datasheet or label for exact chassis dimensions and materials used; ensure mechanical compatibility with your installation. - Electrical interface: Designed for active-low control inputs; check system wiring to match NPN-NO sensor outputs or equivalent active-low drivers. Important operational notes - A short or transient limit signal will stop motion immediately and the controller will remain in the stopped state until a new forward or reverse command (as appropriate) is applied. - After a limit-triggered stop, removing the limit signal does not automatically restart motion. - Use sensors and switches that provide active-low outputs (or adapt outputs to active-low) to ensure reliable operation. - K1 = external forward command, K2 = external reverse command, SW1 = forward stop/limit, SW2 = reverse stop/limit (all follow the same active-low/sensor compatibility). Typical applications (practical scenarios) - Automated sliding gate: Use a momentary push-button (K1/K2) or NPN-NO sensor to start forward/reverse motion; SW1/SW2 act as final-limit switches to prevent overtravel. - Conveyor indexing and safety: Motor advances on a forward command and holds until a programmed stop or a limit switch (SW1) is reached; transient limit signals halt the conveyor and require a deliberate restart. - Motorized valve or actuator control: Simple forward/reverse control with reliable stop signals to protect mechanical endpoints and ensure controlled restarts. Compatibility checklist before installation - Confirm control inputs and sensors provide active-low signals or that you can convert them to active-low. - Verify use of three-wire NPN-NO sensors when applicable. - Map external controls to K1 (forward), K2 (reverse), SW1 (forward limit), and SW2 (reverse limit) per the wiring diagram in your product documentation. Safety and troubleshooting tips - Test limit switches and sensors for correct active-low operation before commissioning. - If the motor does not restart after a stop, ensure the appropriate forward/reverse command is reissued (the system will not auto-restart when a limit clears). - Consult the product wiring diagram and electrical ratings before connecting sensors or external switches. This description preserves the PO version behavior and signal requirements: self-locking forward/reverse control, trigger-type level-activated limit signals that latch stop conditions, and active-low input compatibility including three-wire NPN-NO sensors for K1, K2, SW1, and SW2.
  • Fruugo Kimliği: 392781974-840135018
  • EAN: 525287158423

Teslimat ve İade

24 saat içinde kargoya verilir

  • STANDARD: ÜCRETSİZ - Arasında teslimat Sal 02 Aralık 2025–Per 18 Aralık 2025 - ÜCRETSİZ

Kargo çıkış noktası Çin.

Sipariş ettiğiniz ürünlerin size bütün ve belirttiğiniz özelliklere göre teslim edilmesi için elimizden gelenin en iyisini yapıyoruz. Fakat, bütün gelmeyen veya siparişiniz ettiğinizden farklı çıkan bir ürünün elinize ulaşması ya da siparişinizden başka bir sebepten ötürü memnun kalmamanız durumunda, siparişi veya siparişe dahil ürünlerden herhangi birini iade edebilir ve ürünler için tam para iadesi alabilirsiniz. Tam iade politikasını görüntüle

Ürün Uyumluluk Ayrıntıları

Lütfen aşağıda özetlenen bu ürüne özel uyumluluk bilgilerine bakın.

Aşağıdaki bilgiler bu ürünü satan bağımsız üçüncü taraf perakendeci tarafından sağlanmaktadır.

Üretici:
Aşağıdaki bilgiler, Fruugo tarafında satılan bahsi geçen ürünün üreticisinin irtibat bilgilerini ortaya koymaktadır.

  • DelightDelight
  • Shenzhen Kulomi Technology Co., Ltd.
  • 401-13, Jinhe Building, 8 Xinhe Street, Maan Tang, Bantian
  • Longgang, Shenzhen, Guangdong
  • China
  • Shenzhen
  • CN
  • 518129
  • utopiadealsta@outlook.com
  • 13380310353

AB sınırları içerisindeki Sorumlu Kişi:
Aşağıdaki bilgiler AB sınırları içerisindeki Sorumlu Kişi’nin irtibat bilgilerini ortaya koymaktadır. Sorumlu kişi AB içerisinde konumlu olan atanmış iktisadi işlemcidir, Avrupa Birliği içerisinde satılan bahsi geçen ürün ile ilgili uygunluk yükümlülüklerinden sorumludur.

  • Synertrade FR SAS
  • Synertrade FR SAS
  • 9 rue du Bat d'Argent
  • Lyon
  • France
  • Lyon
  • FR
  • 69001
  • info@syner-sarl.cn
  • (+33)774555006
  • https://seller.kuajingmaihuo.com/settle/qualification-service